Compressed air flow measurementvortex shedding meter. Find vortex flow meter companies that can design, engineer, and manufacture vortex flow meter to your companies specifications. Available with wafer style or flanged style ansi class 150 to ansi class 900, digitalyewflo has the size you need. The rngrwgrwbg series vortex shedding flow meter family is designed to provide accurate and repeatable gas flow measurement.
An everyday example of a vortex shedding phenomenon is a flag waving in the breeze. Titan discuss flow meter vortex shedding if you place an obstruction such as a bluff body in a fluid stream vortices will be formed downstream of the impediment. The system shall utilize the vortex measurement principle by monitoring the shedding frequency of. Our calibration capabilities include a wide range of flow rates, temperatures, and pressures utilizing numerous test gasses. Meter accuracy is good over a potentially wide flow range, although this range is dependent upon operating conditions. Smartflow addresses this limitation by combining vortex shedding flow measurement techniques with fbg sensing advantages.
Processing technology make measurement more stable and reliable. Numerical simulations of bluff body shapes such as circular, rectangular and equilateral triangular have been carried out to understand the phenomenon of vortex shedding. The strouhal number st is a dimensionless number which is a function of the shape and size of the vortex shedder. Final 20140922 performance testing fibre optic based. Vortex flow meters flow instrumentation badger meter. Combined with flexible tuning, the model 84 has the widest flow range capability of any vortex meter. Applications in the chemicals and petrochemicals industries, for example, in power generation and heatsupply systems involve widely differing fluids. The shedder bar is shaped to allow process fluid to separate and generate vortices around. Traditional vortex installations in critical applications include a bypass line to allow process fluid to be redirected around the vortex flow meter during routine sensor maintenance. The versaflow vortex shedding flow meter detects the vortices that are created by a process medium going past a bluff body. The fv200 series vortexshedding fl ow meter is a generalpurpose electronic liquid fl ow meter. Vortex shedding flow meter performance at high flow. A market leading process measurement device, the versaflow vortex shedding flow meter is designed with steam and gas applications in mind. Pfa vortex flowmeter as fluid passes through the flow chamber, karman vortices are created, with frequency proportional to flow velocity.
Vortex flowmeter for vapor, liquid and gas, with integrated binary output. Flow monitors vortex shedding flowmeter description this flowmeter is made for water, waterglycol coolant of low viscosity fluids. The piping system must create some backpressure on the meter to allow vortex formation and to prevent cavitation, especially at full flow. Thorntons pfa flowmeter combines the vortex shedding principle with an advanced ultrasonic detection system. Browse online, or one of our applications engineers can help you choose the right product for your application.
A small obstruction called a bluff body is placed in the flow path. Ultrasonic waves are transmitted through the side wall. A vortex flow meter is a flow measurement device best suited for flow measurements where the introduction of moving parts presents problems. Vortex shedding is a phenomenon, when the wind blows across a structural member, vortices are shed alternately from one side to the other, and where alternating lowpressure zones are generated on the downwind side of the structure giving rise to a fluctuating force acting at right angles to the wind direction. Reducer vortex extends the measurable flow range, reduces. These applications are found in most process industries, including rubber, steel, fabrication, manufacturing. As fluid moves across a vortex meter shedder bar, vortices form. Vortex flowmeter flange card type vortex flowmeter tempersturepressure compensaton type vortex flowmeter inserted type vortex flowmeter sanitaryclamp type lugbtype 2 vortex flow sensor measuring the flow of liquid of steam,gas and low viscosity relationship. It can be mounted with flow in any direction and the display can be rotated 180 degrees in the field for viewing conve nience. The shedding frequency is a function of the dimensions of.
Yokogawa yf108 vortex shedding making use of the individual meter evaluation results, combined with experience of wib member flow experts, an application guideline for vortex flowmeters was prepared by tno. Vortex flow meters operate under the vortex shedding principle, where an oscillating vortexes occur when a fluid such as water flow past a bluff. Vortex shedding flow meter performance at high flow velocities. Model 83 vortex shedding flowmeter flow measurement measure liquids, gases and steam wide rangeability pulse, analogue and digital outputs easy installation no moving parts cenelec, csa, fm and saa approval versions include sanitary, nace and remote electronics general description the 83 series flowmeters measure flow by. Vortex flow meters have now become very popular among the researcher to use it in industries and companies. The variation of st with re is discussed so that the audience has an understanding of what flow features.
Vortex shedding flow meter operating under the same principle of the vortex shedding measurement, this type of vortex flow meter is suitable for viscous,clean, or dirty waterlike liquids that are compatible with brass, pvdf, and fkm. Picture of the fibre optic vortex flow meter in the donau test loop of shell. The vortex shedding frequency around a bluff body can be calculated as. Final 20140922 performance testing fibre optic based vortex. Heinrichs messtechnik gmbh instruction manual dvh dve page 6 of 102 2. It is for this reason that this type of flow meter is sometimes referred to as a vortex shedding flow meter. The fv100 is an inline flow meter that utilizes the vortex shedding measuring principle. This technology works by inducing fluctuations in the fluid properties such as pressure, density or viscosity which can be converted into a flow rate. The rvl series vortex shedding flow meter is a generalpurpose electronic liquid flow meter.
The strohaul number is the ratio between the vortex interval i and the shedder bar width d. Product data sheet fmvs83a model 83 vortex shedding. Vortex shedding sure flow products flow meter supplier, flow switch, and sure flow product store. Vortex shedding flow meters have been in use for many years. Vortex flowmeters are used in numerous branches of industry to measure the volume flow of liquids, gases and steam. Tno has developed a fibre optic based vortex shedding flow meter, which is specifically designed to also estimate the amount of liquid present in a two phase flow. Flow monitors vortex shedding flowmeter cp 342 inch maximum flow ranges from 25200 gpm 95750 lpm max pressure 300 psi 20 bar temperature range 32210f 299c coolpoint with rotatable enclosure option viton is a registered trademark for dupont performance elastomers. Provide a loop powered vortex flow meter consisting of flanged full body or wafer design for the measurement of liquid, gas, or steam media.
If the arrangement is symmetrical the swirls will be shed from alternate sides of the obstruction. Racine vortex rvl series vortex liquid flow meters. User manual flow meters from badger meter, dynasonics. The thermister is excellent sensing method when mounted on front face where very. Sensitivity to variations in the process conditions are low and with no moving parts have relatively low wear compared to other types of flow meters.
Then contact the vortex flow meter companies through our quick and easy request for quote form. Product data sheet fmvs83a model 83 vortex shedding flowmeter. F l o w m o n i t o r s universal coolpoint description. Vortex technology yields a meter with no moving parts to hang. Karman vortex flow meter flow knowledge keyence america. When the strohaul number is fixed,the flow velocity can be measured by counting the number of votices. Flow meter calibrations as one of the largest commercial calibration laboratories in north america, we provide a comprehensive range of calibration services. This flow meter vortex shedding phenomenon is true for both gases and liquids. Vortex shedding flow meter designed for gas flow, steam or liquids volume flow, standard volume flow or mass flow measurement. The development of a multichannel vortex flowmeter using a. Classic digitalyewflo vortex flow meters are available in a number of different sizes ranging from 12inch to 16inch.
The primary sensing element of a volumetric flow meter is a vortex shedding velocity sensor. Metering of fluids at high velocities with vortex shedding. Sv series vortex flow meter in welding applications, it is essential to control the flow rate and tempera ture of cooling water to prolong the life of the welding tip and to assure that the weld cools rapidly for optimum quality. They are available in industrial grade, brass or all plastic construction. Ky instrument emag luxz intelligent vortex precession flow meter the luxz series intelligent vortex precession flow meter is the new type gas flow instrument with domestic leading level developed by our company. Vortex flow meters are suitable for measuring steam as well as a variety of liquids and gases. The frequency of these vortices can be equated into flow velocity, which, in turn, is used to calculate volumetric flow rate. Three vortex shedding cycles or 300 ms, whichever is greater. In this flow, vortices are created at the back of the body and detach periodically from either side of the body. Port sizes available from 38 three eighths inches to 2 two inches in diameter. Maximum flow ranges from 4200 gpm 22750 lpm max pressure 300 psi 20 bar temperature range 35f 254c viton is a registered trademark for dupont performance elastomers. Higher backpressures are required at elevated temperatures and.
When there is a columnshaped obstruction vortex shedder in flowing fluid, it will generate alternating vortices downstream. A0019373 the calibration factor kfactor is used as the proportional constant. Vortex shedding bluff body receiver flow housing transmitter ultrasonic waves karman vortex. This article uses material from the wikipedia article vortex flow meter, which is released under the creative commons attributionsharealike license 3. The three wire version power supplied separate from the. This property of the flow meter makes it very suitable for use in steambased oil recovery applications. Emco engineering measurements companydro flow series of vortex flowmeters are designed specifically for flow water measurement. Pdf design and development of 16 inch vortex flow meter with. Vortex shedding information about the vortex range vortex and other types of oscillatory flow meters utilize the behaviour fluid oscillations in order to derive flow rate. Flow measurement is the quantification of bulk fluid movement. Flow monitors plastic vortex shedding flow rate transmitters description the p420. The purpose of these guidelines was to give some rules of thumb to realise the best possible vortex flowmeter performance. Vortex shedding sure flow products flow meter supplier.
The dvz senses the flow rate of low viscosity liquids using the vortex shedding principle. A vortex meter primary flow element produces a series of oscillations of pressure. Options for a 0 to 5 vdc or a frequency output proportional to the volumetric fl ow rate are also available. The vortex shedding meter provides a linear digital or analog output signal without the use of separate transmitters or converters, simplifying equipment installation.
The standard output is a two wire loop powered 420 ma current. Sierra was the first to offer this unique solution for measuring the mass flow of gases, liquids and steam. Basic working principle of vortex flowmeter instrumentation. Therefore, the frequency of vortex shedding is proportional to the volume flow. Volume flow measurement is enough for substances with small variations in density such as liquid. Eliminate bypass piping for critical process installations. They rely on vortex shedding and require a certain minimum flow velocity to generate the vortices the frequency is linearly related to the fluid velocity.
Archived pdf from the original on 25 september 2015. The meter has no moving parts, and any potential for fluid contamination is eliminated by the corrosionresistant all plastic. Vortex flow meters operate under the vortex shedding principle, where an oscillating vortexes occur when a fluid such as water flow past a bluff as opposed to streamlined body. The result is a meter capable of withstanding extremes of temperature, vibration, magnetic field and radiation, whilst operating in hazardous areas without expensive associated ex rated electronics. Vortex flow meter manufacture silver automation instruments offer china factory made vortex type flow meter at low price cost rugged construction, our factory also deliver the vortex shedding flow meter fast. This figure is a plot showing the strouhal number st, stdfvsu versus the reynolds number re, reud. Digital vortex mass flow meters all feature large lcd display, shows the instantaneous instant flow rate, total flow, temperature, and density in user selectable units. The meter has no moving parts, and any potential for fluid contamination is eliminated by the meters corrosionresistant all plastic. In a vortex flow meter, an obstruction in the flow path, often referred to as a shedder bar, serves as the bluff body. Flow monitors vortex shedding flowmeter and temperature transmitter ct 142 inch flow and temperature transmitter maximum flow ranges from 4200 gpm 15750 lpm max pressure 300 psi 20 bar temperature range 32210f 299c flow temp coolpoint with rotatable enclosure viton is a registered trademark for dupont performance elastomers. The fibre optic cable is the yellow cable shown left of the meter.
This will minimize potential measurement errors by allowing the condensate or solids to flow under the shedder bar without interrupting the vortex shedding. The outputs include 420 ma and pulse for flow rate, as well as high and low alarms. Minimum required backpressure is 10 psig at maximum flow and at 70 f 21 c. Vortex tech nology yields a meter with no moving parts to hang up or wear. Vortex flow meter based on phenomenon is known as vortex shedding. As shown in picture, in the meter body vertical insert a triangular prism root. In fluid dynamics, vortex shedding is an oscillating flow that takes place when a fluid such as air or water flows past a bluff as opposed to streamlined body at certain velocities, depending on the size and shape of the body. The universal flow monitors ufm vortex shedding flow meter is designed for monitoring wateradd on concrete trucks. Ky instrument emag luz intelligent vortex shedding flow meter the electromagnetic velocity meter is portable instrument used for measuring the velocity, flow and level.
Flow meter manuals, drawings, certifications, and other documents. The rosemount 8800d critical process vortex increases process availability and enhances overall safety. Vortexmaster fsv430, fsv450 vortex flowmeter abb group. Vortex flow meters have been appreciated by users as volume flow meters, which can, in principle, be applied to any flow measurement of liquid, gas, or steam. Working principle of vortex flow meter instrumentationtools. The flowmeter contains no moving parts for low maintenance and features a turndown ratio of at least 30. It features the functions of flow rate, temperature and. Higher backpressures are required at elevated temperatures and occasional surges to 125% of maximum flow.
The rvl series meter utilizes vortexshedding technology to provide a repeatable flow measurement accurate to 1% of full scale. We reserve the right to change the technical data in this manual in the light of any technical. The frequency of the vortices shedding is proportional to the fluid velocity. Incorporates temperature sensor into the vortex meter using the shedder bar as a thermowell, which keeps the vortex and temperature sensors isolated from process for easy verification and replacement. These shed vortices are carried downstream in the flow and are detected by vortex shedding and fluidic flow meters, which measure thevelocityof liquids and gases such as water,cryogenicliquids,boiler feed water,hydrocarbons, chemicals, air, nitrogen,industrial gases, and steam flowing through the pipe. Usually the vortex interval is about six times the shedder bar width. The vortex flowmeter is a broadspectrum flow meter which can be used for metering, measurement and control of most steam, gas and liquid flow for a very unique medium versatility, high stability and high reliability with no moving parts, simple structure and low failure rate. The vortex meter in a vortex flow meter, the bluff body is known as a shredder bar. Interestingly the flow meter vortex shedding effect can be seen to occur in everyday life. Dvh dve vortex flowmeter operating manual kobold usa. Vortex shedding flow meter, also called vortex flow meter. The maximum temperature for integral electronics is dependent on the ambient temperature where the flowmeter is installed.
Options for a 0 to 5 vdc or a frequency output proportional to the volumetric flow rate are also available. The analog 420 ma output signal offers your choice of volumetric or mass flow rate. The flowmeters case features a 4digit local display to show the current flowrate measurement and red warning lights to visually indicate high and low flowrate alarms. Vortex shedding flow meter, easy installation, low cost, analog and 420ma output. Simulation of current and binary output manual process execution. If the cylindrical structure is not mounted rigidly and the frequency of vortex shedding matches the chimneys constructed of thinwalled steel tube can be sufficiently flexible that, in air flow with a speed in the critical range, vortex shedding can drive the chimney into violent oscillations that can damage or destroy the chimney. The 83 series vortex flowmeter is available in 3 electonics versions, as shown in the table below. With d and t electronics, combinations of the output signals can be provided, depending on whether the flowmeter is wired as a 2, 3 or 4 wiredevice.
When fluid moves in a pipe then vortices will form when flow hit the bluff body. Vortex flowmeters, also know as vortex shedding flowmeters or oscillatory flowmeters, measure the vibrations of the downstream vortexes caused by a barrier in the moving stream. Vortex flow meter manufacturers suppliers iqs directory. Vortex flow meter rvl series vrxds01586en03 may 2015 product data sheet description the rvl series meter uses vortexshedding technology for repeatable flow measurement accurate to 1 percent of full scale.
Vortex shedding flow meter is suitable for measuring steam flow rate as well as liquids and gases. These meters employ a patented ultrasonic technique to measure a form of turbulence created in the flow stream. The meters have no moving parts and are virtually maintenancefree. Vortex meters see the most use in terms of steam application, since in relation to alternative forms of flow measurement, a vortex flow meter used as a steam flow meter features no moving parts, has a long functional working life, and is not too expensive. The vibrating frequency of the vortex shedding is related to the velocity of the flow. Refer to the product reference manual for typical flow rates for common applications. Plastic vortex meters cx series open email download. The flapping of a flag is probably the most common example of this effect. Temperature compensated capability for saturated steam. Top vortex flow meter brands such as below, has excellent performance. The kobold dvz series vortex flowmeters are the perfect solution for applications where reliability and low cost are desired. The result is a simpler, more reliable design that is more sensitive to flow and less sensitive to noise. With builtin temperature compensation as a standard feature and optional integral pressure compensation, it is the first choice for saturated steam, superheated steam and compensated gas flow measurement.
664 950 347 1233 733 638 567 963 310 1608 148 228 202 1011 1089 559 1270 447 1556 21 1158 108 1227 538 1412 1009 920 271 300 1255 1269 803 1236 31 19 243 141 1340 515